S5735-L24P4X-A1 DATASHEET

S5735-L24P4X-A1 Specification

Dimensions without packaging (H x W x D) [mm(in.)]

Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.)

Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.)

Dimensions with packaging (H x W x D) [mm(in.)]

90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.)

Chassis height [U]

1 U

Typical power consumption [W]

42.4 W

Typical heat dissipation [BTU/hour]

144.67 BTU/hour

Maximum power consumption [W]

  • Not providing the PoE function: 53.8 W
  • 100% PoE loads: 433.8 W (PoE: 380 W)

Maximum heat dissipation [BTU/hour]

  • Not providing the PoE function: 183.57
  • 100% PoE loads: 1480.17

MTBF [year]

52.74 year

MTTR [hour]

2 hour

Availability

>0.99999

Noise at normal temperature (acoustic power) [dB(A)]

50 dB(A)

Noise at normal temperature (acoustic pressure) [dB(A)]

38.2 dB(A)

Number of card slots

0

Number of power slots

0

Number of fans modules

2

Redundant power supply

Not supported

Long-term operating temperature [°C(°F)]

-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)

Short-term operating temperature [°C(°F)]

-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)

Restriction on the operating temperature variation rate [°C(°F)]

When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:

  • The equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year.
  • The equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year.
  • The equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year.

The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.

The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.

Storage temperature [°C(°F)]

-40°C to +70°C (-40°F to +158°F)

Long-term operating relative humidity [RH]

5% to 95%, noncondensing

Long-term operating altitude [m(ft.)]

0-5000 m (0-16404 ft.)

Storage altitude [m(ft.)]

0-5000 m (0-16404 ft.)

Power supply mode

AC built-in

Rated input voltage [V]

  • AC input: 100 V AC to 240 V AC, 50/60 Hz
  • High-Voltage DC input: 240 V DC

Input voltage range [V]

  • AC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz
  • High-Voltage DC input: 190 V DC to 290 V DC

Maximum input current [A]

6 A

Memory

512 MB

Flash memory

512 MB

Console port

RJ45

Eth Management port

Not supported

USB

Supported

RTC

Not supported

RPS input

Not supported

Service port surge protection [kV]

98011318:

Common mode: ±7 kV

98011318-001:

Common mode: ±2 kV

Power supply surge protection [kV]

±6 kV in differential mode, ±6 kV in common mode

Types of fans

Built-in

Heat dissipation mode

Heat dissipation with fan, intelligent fan speed adjustment

Airflow direction

Air intake from left and front, air exhaustion from right

PoE

Supported

Certification

EMC certification

Safety certification

Manufacturing certification